MICROPROCESS RPM & LINE-SPEED CONTROLLER METER (PULSE INPUT) / Model:MRS-S
Accuracy 0.03% F.S.
Measuring Pulse(TTL,CMOS), Magnetic pick-up signal
Accept input rates up to 50 KHz
Display type of RPM or line-speed can be modified
Input pulse of revolution can be modified
(1-99999 pulse / revolution)
Two alarm function (Optional)
16 bit DAC analog output function (Optional)
Digit RS-485 interface function (Optional)

----------------------------------------------------------------------------------

 
MICROPROCESS LENGTH,FLOW CONTROLLER METER (PULSE INPUT)/ Model:MMC
Readout range form -19999 to 99999
Accept input rates up to 10KHz
Accept input rates 50 or 5000 CPS can be modified
Four counting modes Up,Down,quadrature can be modified
Quadrature sensing up to 4 times resolution
Input scaling multiplied 0.0001 to 9.9999 can be modified
Two alarm function (Optional)
15 bit DAC analog output function (Optional)
Digit RS-485 interface function (Optional)
 
----------------------------------------------------------------------------------
 
MICROPROCESS RPM & LINE-SPEED CONTROLLER METER (PULSE INPUT) / Model:MMR
Accuracy 0.03% F.S.
Measuring Pulse(TTL,CMOS), Magnetic pick-up signal
Accept input rates up to 50 KHz
Display type of RPM or line-speed can be modified
Input pulse of revolution can be modified
(1-99999 pulse / revolution)
Two alarm function (Optional)
15 bit DAC analog output function (Optional)
Digit RS-485 interface function (Optional)
 
----------------------------------------------------------------------------------
 
MICROPROCESS RATE & TOTALIZER CONTROLLER METER / Model:MRT
Programable rate 0 to 19999 digit (rate),0 to 999999999 digit (totalizer)
Accuracy 0.1% F.S. 1digit
Programable time base (1,60,3600 second)
Programable scale factor (0.00001 to 9999.99999 )(totalizer)
Math-rootextractor function
Dual alarm function (Optional)
15 bit DAC isolating analog output function (Optional)
Digit RS-485 interface function (Optional)
Digit pulse output function (Optional)
 
----------------------------------------------------------------------------------
 
MICROPROCESS RATE & TOTALIZER CONTROLLER METER (PULSE INPUT) / Model:MFRT
Programable rate 0 to 19999 digit (rate),0 to 999999999 digit (totalizer)
Accuracy 0.03% F.S. (rate)
Input range form 0.01 Hz to 10 KHz
Programable time base (1,60,3600 second)
Programable scale factor (0.00001 to 9999.99999 )(totalizer)
Dual alarm function (Optional)
15 bit DAC isolating analog output function (Optional)
Digit RS-485 interface function (Optional)
Digit pulse output function (Optional)
 
----------------------------------------------------------------------------------
 
MICROPROCESS DUAL INPUT RPM & LINE-SPEED MATHS CONTROLLER METER / Model:MMX-R
Accuracy 0.03% F.S.
Measuring Pulse(TTL,CMOS), Magnetic pick-up signal
Dual input math function B-A,B/A,(B/A)-1,B/(A+B)
Accept input rates up to 50 KHz
Display type of RPM or line-speed can be modified
Input pulse of revolution can be modified
(1-99999 pulse / revolution)
Two alarm function (Optional)
15 bit DAC analog output function (Optional)
Digit RS-485 interface function (Optional)
 
----------------------------------------------------------------------------------
 
MICROPROCESS RPM & LINE-SPEED METER (DISPLY 0.8")/ Model:MMX-L
Accuracy 0.1% F.S. 1digit
Measuring Pulse(TTL,CMOS), Magnetic pick-up signal
Accept input rates up to 50 KHz
Display type of RPM or line-speed can be modified
Display unit M/min, Y/min can be modified
Input pulse of revolution can be modified (1-99999 pulse / revolution)
Decimal point can be modified
One alarm function (Optional)
Dimension small and High stability
 
----------------------------------------------------------------------------------
 
MICROPROCESS RPM & LINE-SPEED METER, 24*48mm / Model:MRS
Accuracy 0.05% F.S.
Measuring Pulse (TTL,CMOS)Magnetic pick-up
Accepts input rates up to 50KHz
Display type of RPM or line-speed can be modified
Display unit M/min Y/min ft/min can be modified
Inpout pulse of revolution can be modified(1-99999)
Decimal point can be modifed
Dimension small and High stability
 
----------------------------------------------------------------------------------
 
MICROPROCESS RPM & LINE-SPEED METER / Model:MR
Accuracy 0.01% F.S.
Measuring pulse (TTL,CMOS), Magnetic pick-up
Display type of RPM or line-speed can be modified
Display unit M/min,Y/min,ft/min can be modified
Input pulse of revolution can be modified(1-9999)
Decimal point can be modifed
Dimension small and High stability
 
 
TEL:886-2-2276-3475 / FAX:886-2-2276-3479 / E-mail:axe168.mail@msa.hinet.net
No.70,Lane 83, Hwa Chen Road, Hsing Chuang City,Taipei Hsien
> Digital meter
> Controller meter
> Flow controller meter
> Counter
> Power meter
> Transmitter
> Slim type transmitter
> Microprocess transmitter
> Power transducer
 
> Download Adobe Reader
> Download ModBusTest