PLUG-IN POWER MONITOR ,LCD DISPLAY
Model:AXE-0
 
Accuracy0.25%F.S.
Measuring and display ACV/ACA/Watt/VA/Frequency/Power factor /KWH/KWH time
ACV/ACA/Watt for ture RMS
ACA/Watt/VA/KWH/KWH time auto-range function
Large LCD character high 16.3mm(1.146")
Impulse test meet requirement of IEC 60950-1 6KV/3KA combination wave test
Surge test (ring wave)2.5KV(0.25ms/1MHz)(IEC255-4)
 

---------------------------------------------------------------------------------

 
 
 
PLUG-IN POWER MONITOR
Model:AXE-1

CAD Drawing

Accuracy0.1%F.S.

Measuring and display ACV/ACA/Watt/VA/Frequency/Power factor /KWH/KWH time
ACV/ACA/Watt for ture RMS
ACA/Watt/VA/KWH/KWH time auto-range function
Over current (>15A) and over temperature(>65C)auto-protector function
Large bright whiteLEDs high 16.3mm(1.146")
Impuse test Meet requirement of IEC 60950-1 6KV/3VA combination wave test
Surge test (ring wave)2.5KV(0.25ms/1MHz))(IEC255-4)
 

--------------------------------------------------------------------------

 
PLUG-IN POWER CONTROLLER
Model:AXE-2
 

Accuracy0.1%F.S.

Measuring and display ACV/ACA/Watt/Frequency/Power factor /KWH/KWH time
ACV/ACA/Watt for ture RMS
ACA/Watt/KWH/KWH time auto-range function
Over current (>15A) and over temperature(>65C)auto-protector function
Impulse test meet requirement of IEC 60950-1 6KV/3KA combination wave test
One load control relay function
Digit RS-485 interface function (Optional)
 

---------------------------------------------------------------------------------

 
 
MULTI-FUNCTION POWER METER ,(96x96mm)
Model:MMP-2
Accuracy 0.25% F.S.
Measuring and display ACV/ACA/Watt/Var/Power factor/Frequency/KWH/DM(Demand)
Input measurement network can be selectives(1P2W/1P3W/3P3W/3P4W)
CT rate/PT rate can be modified(1 to 9999)
Manual or auto scanning mode can be modified
Two alarm control function (optional)
Two pulse output function (optional)
Digit RS-485 interface function (Optional)
   

-----------------------------------------------------------------------

 
 
MULTI-FUNCTION POWER METER(48x96mm)
Model:MMP-3
Accuracy0.15% F.S.
Measuring ACV/ACA/Watt/Var/Power factor/Frequency/KWH)
Input measurement network can be selectives(1P2W/1P3W/3P3W/3P4W)
CT rate/PT rate can be modified(1 to 9999)
Manual or auto scanning mode can be modified
Three alarm control function (optional)
Digit RS-485 interface function (Optional)
CE EMC certification
 

-------------------------------------------------------------------------

3 PHASE AC VOLTAGE/CURRENT METER(48x96mm)
Model:MMP-3VI
Accuracy 0.15% F.S.
Measuring ACV-line/ACV-phase/A
CT rate/PT rate can be modified(1 to 9999)
Manual or auto scanning mode can be modified
Surage test 4KV(1.2x50us)
Three alarm control function (optional)
Digit RS-485 interface function (Optional)
CE EMC certification
 

-----------------------------------------------------------------------

5 DIGITAL FREQUENCY METER(48x96mm)
Model:MF
Accuracy 0.01% F.S.
Measuring AC Frequency, Pulse(TTL,CMOS) Frequency
Accept input rates up to 50KHz
Decimal point can be modifed
Dimension small and High stability
CE EMC certification
 

--------------------------------------------------------------------------

MICROPROCESS AC POWER CONTROLLER METER(48x96mm)
Model:MMP
Accuracy 0.25% F.S.1digit
Measuring watt/var/power factor/phase angle
Programmable rate 0 to 19999 digit
Dielectric strength 2KVac/1min(input/output/power)
Surage test 4KV (1.2X50us)
Dual alarm function (Optional)
15 bit DAC analog output function (Optional)
Digit RS-485 interface function (Optional)
CE EMC certification
 
--------------------------------------------------------------------------
MICROPROCESS AC MULTI-POWER METER (1P2W)(48x96mm)
Model:MMX-P1
Accuracy 0.25% F.S.1digit (ACA/ACV/WATT/VA)
Measuring ACA/ACV/Frequency/WATT(power factor or Apparent power )
ACA/ACV/WATT for Ture RMS)
ACA/WATT decimal point can be modifed
CT rate can be modifed(1 to 999)
Dielectric strength 2KVac/1min(input/output/power)
Surage test 4KV (1.2X50us)
Digit RS-485 interface function (Optional)
CE EMC certification
 
--------------------------------------------------------------------------
MICROPROCESS WATT/WATTHOUR (VAR/VARHOUR) CONTROLLER METER (48x96mm)
Model:MPH
Accuracy 0.25% F.S.1digit
Programmable rate 0 to 19999 digit(rate),0 to 999999999 digit(totalizer)
Programmable scale factor (0.0001 to 99999.9999)(totalizer)
Dielectric strength 2KVac/1min(input/output/power)
surage test 4KV (1.2X50us)
Dual alarm function (Optional)
Digit RS-485 interface function (Optional)
Digit pulse output function (Optional)
CE EMC certification
 

 

TEL:886-2-2276-3475 / FAX:886-2-2276-3479 / E-mail:axe168.mail@msa.hinet.net

E-mail:axe@axe168.com.tw


No.70,Lane 83, Hua Cheng Road, Xinzhuang Dist., New Taipei City 24252,Taiwan(R.O.C)

 
> NEW PRODUCT
> SENSOR
> Digital meter
> Controller meter
> Flow controller meter
> Counter
> Power meter
> Transmitter
> Slim type transmitter
> Microprocess transmitter
> Power transducer
> Download Adobe Reader
> Download ModBusTest