TEMPERATURE & HUMIDITY SIGNAL TRANSMITTER & CONTROLLER METER RELAY
|
Model:THM |
|
|
|
Accuracy±0.15%℃(Temperature),±1%RH(Humidity) |
|
Measuring -40~+120℃(Temperature),0~100%RH(Humidity) |
|
Response time within 20 second (0~90% at 1M/s air flow) |
|
Two 12bit DAC analog output function (option) |
|
Two alarm controller function (option) |
|
Digit RS-485 interface function (option) |
|
Protection class NEMA 4/IP65 |
|
|
|
----------------------------------------------------------------------- |
|
|
|
6 DIGIT TIME COUNTER CONTROLLER,24x48mm
|
Model:MT24 |
|
|
|
Timing start mode(Power on or external contact or NPN or DC4~30V pulse signal input can be modified |
|
4 type timer counting for (9999.99Hour/ 9999Hour59Minute/99Hour59Minute59Secon/ 9999Day23Hour) can be modified) |
|
Timer eleven output mode(A/A1/A2/A3/A5/B/B1/B2/C/D/E can be modified) |
|
One alarm output function |
|
Dimension small and High stability |
|
CE EMC certification |
|
|
|
----------------------------------------------------------------------- |
|
|
|
TEMPERATURE & HUMIDITY SIGNAL TRANSMITTER
|
Model:STH-1 |
|
|
|
Accuracy±0.15℃(Temperature),±1%RH(Humidity) |
|
Measuring -40~+80℃(Temperature),0~100%RH(Humidity) |
|
Response time within 20 second (0~90% at 1.0M/s air flow) |
|
Field-rangeable supply voltage from DC10 to 28V |
|
Two 12 Bit DAC analog output function (option) |
|
Digit RS-485 interface function (option) |
|
Double waterproof treatment |
|
Protection class NEMA 4/IP65 |
|
|
|
----------------------------------------------------------------------- |
|
|
|
TEMPERATURE & HUMIDITY SIGNAL TRANSMITTER (SUS 304 PROB)
|
Model:STH-2 |
|
|
|
|
|
----------------------------------------------------------------------- |
|
|
|
SPECIAL WATT-HOUR METER FOR SEPARATE BILLING OF ELECTRIC VEHICLE CHARGING PILES,24X48mm
|
Model:MMS-PWH |
|
|
|
Accuracy ±0.2% F.S. |
|
Measuring and display ACV/ACA/KW/KWH/Power Factor |
|
ACV/ACA/KW for Ture RMS |
|
Surage test 4KV(1.2x50us,) |
|
Digit RS-485 interface function |
|
Dimension small(24x48x48.5mm) and High stability |
|
Discrete terminal,connector easy |
|
|
|
----------------------------------------------------------------------- |
|
|
|
SLIM TYPE SPECICAL FUNCTION ISOLATED TRANSMITTER
& CONTROLLER METER RELAY
|
Model:SSFTR |
|
|
|
Accuracy 0.05% F.S. ±1digit |
|
Measuring DCA/DCV/ACA/ACV/Potentiometer /Transmitter/Pt-100/Resistor/etc.... |
|
Programmable rate -19999~99999 digit |
|
Specical function Ramp buffer/Delay buffer/Maximum hold/minimun hold/Hold/Track |
|
Two relay output function (optional) |
|
16 bit DAC analog output function (optional) |
|
Digit RS-485 interface function (optional) |
|
Wide input range for auxiliary power |
|
|
|
----------------------------------------------------------------------- |
|
|
|
MICROPROCESS AC CURRENT/
AC VOLTAGE CALIBRATOR METER(48x96mm)
|
Model:MAG |
|
|
|
Accuracy ±0.1% F.S. |
|
Calibrator for AC current(AC0~5.000A)/AC voltage(AC0~99.99V/600.0V) |
|
AC output frequency 45.0 to 65.0Hz adjustable function |
|
Digit RS-485 interface function(optional) |
|
Dimension small and High stability |
|
|
|
----------------------------------------------------------------------- |
|
|
|
MICROPROCESS 6 CHANNEL INPUT ISOLATD
CONTROLLER METER(48x96mm)
|
Model:MM8I |
|
|
|
Accuracy 0.1% F.S. ±1 digit |
|
Measuring DCA/DCV/ACA/ACV/Thermocouple/etc... |
|
Programmable rate -1999~9999 digit |
|
Input channel number(1~6) can be modified |
|
Two alarm function(optional) |
|
Digit RS-485 interface function(optional)
|
|
|
|
----------------------------------------------------------------------- |
|
|
|
SLIM TYPE MULTI-FUNCTION RS-485
CONTROLLER METER RELAY
|
Model:SMRSR |
|
|
|
Analog output accuracy±0.05% F.S. |
|
Readout range from -19999~99999 digit |
|
Calibrator analog output for DC4~20.000mA/0~20.000mA/0~10.000V) |
|
Modbus RTU mode for RS-485 protocal |
|
Two relay output function (optional) |
|
16 bit DAC analog output function (optional) |
|
Dimension small & High stability |
|
|
|
----------------------------------------------------------------------- |
|
|
6 DIGITAL MICROPROCESS PANEL METER(48x96mm) |
Model:MM6 |
|
|
|
Accuracy 0.015% F.S. ± 3digit |
|
Measuring DCA/DCV/ACA/ACV/Potentiometer/ Transmitter/Load Cell... |
|
Programmable rate -999999~999999 digit |
|
Auto zero and maximum hold function |
|
Decimal point can be modified |
|
Digit RS-485 interface function (optional)
|
|
|
|
----------------------------------------------------------------------- |
|
|
|
MICROPROCESS DUAL INPUT (MATH FUNCTION)RPM & LINE-SPEED CONTROLLER METER(48x96mm) |
Model:MMRD-M |
|
|
|
Accuracy 0.03% F.S. |
|
Dual input measuring and display Pulse(TTL,CMOS),Magnetic pick-up signal |
|
Accepts input rates up to 25KHz |
|
Display type of RPM or line-speed can be modified |
|
Input pulse of revolution can be modified(1~99999 pulse/revolution |
|
Four independent alarm function(optional) |
|
16 bit DAC analog output function(optional) |
|
Digit RS-485 interface function(optional) |
|
|
|
----------------------------------------------------------------------- |
|
|
|
MICROPROCESS DUAL INPUT RPM & LINE-SPEED CONTROLLER METER(48x96mm) |
Model:MMRD |
|
|
|
Accuracy 0.03% F.S. |
|
Dual input measuring and display Pulse(TTL,CMOS),Magnetic pick-up signal |
|
Accepts input rates up to 25KHz |
|
Display type of RPM or line-speed can be modified |
|
Input pulse of revolution can be modified(1~99999 pulse/revolution |
|
Two independent alarm function(optional) |
|
16 bit DAC analog output function(optional) |
|
Digit RS-485 interface function(optional) |
|
|
|
----------------------------------------------------------------------- |
|
|
|
5 DIGIT MICROPROCESS DUAL COUNTER(MATH FUNCTION) LENGTH & FLOW CONTROLLER METER(48x96mm) |
Model:MMCD-M |
|
|
|
Accepts input rates up to 10KHz |
|
Dual input measuring and display sensor signal |
|
Three counting modes up/down,direct-up/down,quadrature-up/down can be modified |
|
Quadrature sensing up to 4 times resolution |
|
Input scaling multiplied 0.0001 to 9.9999 can be modified |
|
Four independent alarm function(optional) |
|
16 bit DAC analog output function(optional) |
|
Digit RS-485 interface function(optional) |
|
|
|
----------------------------------------------------------------------- |
|
|
|
5 DIGIT MICROPROCESS DUAL COUNTER LENGTH & FLOW CONTROLLER METER(48x96mm) |
Model:MMCD |
|
|
|
Accepts input rates up to 10KHz |
|
Dual input measuring and display sensor signal |
|
Three counting modes up/down,direct-up/down,quadrature-up/down can be modified |
|
Quadrature sensing up to 4 times resolution |
|
Input scaling multiplied 0.0001 to 9.9999 can be modified |
|
Two independent alarm function(optional) |
|
16 bit DAC analog output function(optional) |
|
Digit RS-485 interface function(optional) |
|
|
|
----------------------------------------------------------------------- |
|
|
|
4~20mA LOOP-POWERED,5 DIGIT LEDs DISPLAY PROCESS MONITORSwith built-in RS-485 (24x48mm) |
Model:MA24-LD |
|
|
|
Accuracy 0.05% F.S. ±1 digit |
|
Programmable rate -19999 to 99999 digit |
|
Self-power,no external supply required |
|
Digit RS-485 interface function (optional) |
|
Dimension small(24x48x48.5mm) and High stability |
|
Discrete terminal,connector easy |
|
CE EMC certification |
|
|
|
----------------------------------------------------------------------- |
|
|
|
MULTI-FUNCTION
TWO-WAY DC METER(48x96mm) |
Model:MM2D-DTT |
|
|
|
Accuracy
0.03% F.S.±1digit |
|
Measuring and display DCV/DCA/W/KW/WH/KWH |
|
Programmable rate -19999 to 99999 digit(rate),-1999999999 to 9999999999 digit(totalizer) |
|
Four
alarm function (optional) |
|
16
bit DAC analog output function (optional) |
|
Digit
RS-485 interface function)(optional) |
|
|
|
|
|
----------------------------------------------------------------------- |
|
|
MICROPROCESS RPM & LINE-SPEED METER(SELF-POWER)(24x48mm) (PULSE INPUT) |
Model:MR24S |
|
|
|
|
|
|
----------------------------------------------------------------------- |
|
|
MICROPROCESS RATE & TOTALIZER METER
(SELF-POWER),24X48mm(PULSE INPUT)
(24x48mm)
|
Model:MFRTS |
|
|
|
|
Self-power,measuring pulse input ,display rate and totalizer |
|
Programmable rate 0 to 99999 digit(rate),0 to 99999999 digit(totalizer) |
|
Accuracy 0.05% F.S.(rate) |
|
Input range form 0.01Hz to 1KHz
|
|
Programmable time base 1 or 60 or 3600 second |
|
Dimension small(24x48x48.5mm) and High stability |
|
Discrete terminal,connector easy |
|
CE EMC certification |
|
|
|
----------------------------------------------------------------------- |
|
|
SLIM TYPE TWO CHANNEL MICROPROCESS ANALOG
SIGNAL INPUT MODULE
|
Model:SDMAI |
|
|
|
Accuracy 0.05% F.S. ±1digit |
|
Measuring DCA/DCV/ACA/ACV/Potentiometer/
Transmitter/Pt-100/Thermocouple/Load Cell/Resistor/etc... |
|
Programmable rate -19999~99999 digit |
|
Two channel input signal isolated output
RS-485 for design |
|
Dielectric strength 1.5KVac/1min(input1/input2/output RS-485/power) |
|
Wide input range for auxiliary power |
|
Dimension small & High stability |
|
|
|
----------------------------------------------------------------------- |
|
|
|
SLIM TYPE TWO CHANNEL MICROPROCESS ANALOG
SIGNAL ISOLATED TRANSMITTER
|
Model:SDMAT |
|
|
|
Accuracy 0.05% F.S. ±1digit |
|
Measuring DCA/DCV/ACA/ACV/Potentiometer/
Transmitter/Pt-100/Thermocouple/Load Cell/Resistor/etc... |
|
Programmable rate -19999~99999 digit |
|
Two channel input signal isolated output
for design |
|
Dielectric strength 1.5KVac/1min
(input1/input2/output1/output2/power) |
|
Wide input range for auxiliary power |
|
Dimension small & High stability |
|
|
|
----------------------------------------------------------------------- |
|
|
|
HEAD-MOUNTED TWO WIRE TEMPERATURE
SIGNAL ISOLATED TRANSMITTER
|
Model:TW-I |
|
|
|
Accuracy 0.1% F.S.(Pt-100),0.2% F.S.0.5℃(CJC)(TC) |
|
Input type (Pt-100/J/K/T/E/R/S/B) can be modified |
|
Output range(-19999~99999)/Display unit(℃,℉)can be modified |
|
Burnout protection function, upscale the
output current limit of approximately≦21mA |
|
Field-rangeable supper voltage from
12 to 28V |
|
Output DC4~20mA,RL(max.)=(Vsupper-12V)/20mA, up to 600 ohms
at 24VDC |
|
Dielectric strength 1.5KVac/1min
(input/output) |
|
HM-1 |
|
----------------------------------------------------------------------- |
|
|
|
ULTRA SLIM TYPE TWO-WIRE ANALOG SIGNAL
ISOLATED TRANSMITTER
|
Model:SSMA-T |
|
|
|
Accuracy 0.1% F.S.(DC/Pt-100),0.2% F.S.0.5℃(CJC)(TC) |
|
Input analog type (DCV/mV/mA/Pt-100/J/K/T/E/R/S/B) can be modified |
|
Burnout protection function, upscale the output current limit of
approximately≦21mA |
|
Field-rangeable two-wire supply voltage from
12 to 28V |
|
Output DC4~20mA,RL(max.)=(Vsupply-12V)/20mA, up to 600 ohms at 24VDC |
|
Dielectric strength 1.5KVac/1min(input/output) |
|
HM-1 |
|
----------------------------------------------------------------------- |
|
|
|
SLIM TYPE TWO CHANNEL ANALOG SIGNAL
ISOLATED TRANSMITTER
|
Model:SDAT |
|
|
|
Accuracy 0.1% F.S. ±1digit |
|
Measuring DCA/DCV/ACA/ACV/Potentiometer
/Transmitter/Pt-100/Load Cell/
Resistor/etc... |
|
Two channel input signal isolat
ed
output fordesign |
|
Dielectric strength 1.5KVac/1min(input1/input2/
output1/output2/power) |
|
Wide input range for auxiliary power |
|
Dimension small & High stability |
|
|
|
----------------------------------------------------------------------- |
|
|
SLIM TYPE TWO-WIRE ANALOG SIGNAL
ISOLATED TRANSMITTER
|
Model:SMA-T |
|
|
|
|
|
----------------------------------------------------------------------- |
|
|
SLIM TYPE TWO-WIRE DC SIGNAL
ISOLATED TRANSMITTER
|
Model:STD-T |
|
|
|
|
|
----------------------------------------------------------------------- |
|
|
THREE WIRE DC SIGNAL ISOLATED
TRANSMITTER (mini-size)
|
Model:TWD |
|
|
|
|
|
----------------------------------------------------------------------- |
|
MULTI-FUNCTION
POWER METER ,(96x96mm) |
Model:MMP-2H |
|
|
|
Accuracy
±0.1% F.S. |
|
Measuring and display ACV/ACA/Watt/Var/VA/Power Factor/Frequency/KWH/
DM(Demand) |
|
Input
measurement network
can beselectives
(1P2W/1P3W/3P3W/3P4W) |
|
Measuring ACV/ACA total
harmonic distortion(THD),
up to 35th harmonic(optional) |
|
Two
alarm control function
(optional) |
|
Two
pulse output function
(optional) |
|
Digit
RS-485 interface function
(Optional) |
|
|
|
|
|
----------------------------------------------------------------------- |
|
|
MICROPROCESS
PANEL CONTROLLER METER (DISPLAY
0.8")(48x96x85mm) |
Model:MM3S |
|
|
|
Accuracy
0.05% F.S.±1digit |
|
MeasuringDCA/DCV/ACA/ACV/Potentiometer/ Transmitter/Pt-100/Thermocouple/Load
Cell/ Resistor/etc... |
|
Programmable
rate -19999~99999 digit |
|
Auto
zero and math-rootextractor and
maximum hold function
|
|
Correction for non-linearity function
(16 segments)(optional) |
|
Max.
four alarm function(optional) |
|
16
bit DAC analog output function(optional) |
|
Digit
RS-485 interface function(optional) |
|
|
|
----------------------------------------------------------------------- |
|
|
DC MULTI-POWER METER
(Smart 485/Low
Power)(48x96mm)
|
Model:MMX-D |
|
|
|
|
|
----------------------------------------------------------------------- |
|
|
|
6 DIGIT MULTI-FUNCTION MICROPROCESS COUNTER/TIMER COUNTER(72x72mm) |
Model:MM726 |
|
|
|
Counter and timer function can be selective |
|
Pulse input type NPN/PNP can be modified |
|
Accept input rates 50 or 50000 CPS
can modified-(Counter) |
|
Five counting modes Front/after edge-up,down,up/down,direct-up/down,
quadrature-up/down can be modified |
|
Counter ten output mode N/F/R/Q/C/P/K
/A/L/H can be modified |
|
Twelve time counting range form 999.999
second to 999999 hour can be modified |
|
Timer eleven output mode A/A1/A2/A3/B/B1/B2/C/D/E/F
can be modified |
|
Protection class NEMA4/IP67 |
|
|
|
----------------------------------------------------------------------- |
|
|
|
6 DIGIT MULTI-FUNCTION MICROPROCESS COUNTER/TIME(48x48mm) |
Model:MM48 |
|
|
|
Auto.change red or green or orange display
when alarm status changes |
|
Counter and time function can be selective |
|
Accept input rates 50 or 10000 CPS can be modified |
|
Five counting input modes Front/
after edge-up,Front/after edge-down,up/
down,direct-up/down,quadrature-up/
down can be modified |
|
Ten output mode N/F/R/Q/C/P/K/A/L/H
can be modified |
|
Twelve time counting range form 999.999
second to 999999 hour can be modified-(Time) |
|
Time eleven output mode A/A1/A2/A3/B/B1/B2/C/D/E/F
can be modified |
|
Two alarm function
|
|
|
|
----------------------------------------------------------------------- |
|
|
6 DIGIT MULTI-FUNCTION MICROPROCESS TIME(48x48mm) |
Model:MT48 |
|
|
|
Auto.change red or green or orange display
when alarm status changes |
|
Pulse input type NPN/PNP can be modified |
|
Pulse input signal time 1ms/20ms
can be modified |
|
Time counting direction Up/Down
can be modified |
|
Twelve time counting range form 999.999
second to 999999 hour can be modified-(Time) |
|
Time twelve output mode A/A1/A2/A3/A5/B/B1/B2/C/D/E/F can be modified |
|
Two alarm function |
|
|
|
----------------------------------------------------------------------- |
|
|
6 DIGITAL ONE/TWO ALARM & 6 DIGITAL TOTALIZER COUNTER(72x72mm) |
Model:MT726 |
|
|
|
|
|
----------------------------------------------------------------------- |
|
MULTI-FUNCTION MICROPROCESS RPM & LINE-SPEED CONTROLLER METER(72x72mm)
|
Model:MR726 |
|
|
|
|
|
----------------------------------------------------------------------- |
|
|
HIGH SPEED MICROPROCESS LENGTH,FLOWCONTROLLER METER(72x72mm) |
Model:MMC726 |
|
|
|
|
|
----------------------------------------------------------------------- |
|
MICROPROCESS PANEL CONTROLLER METER (72x72mm)
|
Model:MA726 |
|
|
|
|
|
----------------------------------------------------------------------- |
|
MICROPROCESS AC CURRENT MONITOR METER(72x72mm)
|
Model:MCM726 |
|
|
|
|
|
----------------------------------------------------------------------- |
|
|
4/6 DIGIT MICROPROCESS COUNTER
(PUSHWHEEL TYPE)(48x96mm)
|
Model:MCP |
|
|
|
Accepts input rates up to 10KHz |
|
Four counting modes Up,Down,Up/Down,quadrature-up/down
can be modified |
|
Quadrature sensing up to 4 times resolution |
|
Input scaling multiplied 0.00001 to 9.99999
can be modified
|
|
Two alarm function (optional) |
|
16 bit DAC analog output function (optional) |
|
Digit RS-485 interface function(optional)
|
|
|
|
----------------------------------------------------------------------- |
|
|
MICROPROCESS PANEL CONTROLLER METER
(48x48mm)
|
Model:MA48 |
|
|
|
Accuracy 0.05% F.S. ±1digit |
|
Measuring
DCA/DCV/ACA/ACV/Potentiometer/
Pt-100/Transmitter/Load
Cell/Resistor/etc... |
|
Programmable rate -19999~99999 digit |
|
Auto zero and hold and maximum hold function |
|
Two alarm function (optional) |
|
16 bit DAC analog output function (optional) |
|
Digit RS-485 interface function (optional) |
|
Protection class NEMA4/IP65 |
|
|
|
----------------------------------------------------------------------- |
|
|
5 DIGIT HIGH SPEED MICROPROCESS COUNTER
(48x48mm)
|
Model:MC48 |
|
|
|
Accepts input rates up to 50KHz |
|
Accept input rates 50 or 50000 CPS
can modified
|
|
Seven counting modes Front/after edge-up,Front/after edge-down,up/down,direct-up/down,
quadrature-up/down can be modified |
|
Quadrature sensing up to 4 times resolution |
|
Input scaling multiplied 0.0001 to 9.9999
can be modified
|
|
Seven output mode N/F/R/Q/C/P/K can be modified |
|
Two alarm function (optional) |
|
16 bit DAC analog output function (optional) |
|
Digit RS-485 interface function (optional) |
|
Protection class NEMA4/IP65 |
|
|
|
----------------------------------------------------------------------- |
|
|
MULTI-FUNCTION MICROPROCESS RPM & LINE-SPEED
CONTROLLER METER(48x48mm) |
Model:MR48 |
|
|
|
Accuracy 0.03% F.S. |
|
Accepts input rates up to 50KHz |
|
Accept input rates 50 or 50000 CPS
can modified
|
|
Dual input math function B-A,B/A,(B/A-1),1-(B/A),B/(A+B) |
|
Display type of RPM or line-speed
can be modified
|
|
Input pulse of revolution can be modified(1~99999 pulse/revolution) |
|
Two alarm function (optional) |
|
16 bit DAC analog output function (optional) |
|
Digit RS-485 interface function (optional) |
|
Protection class NEMA4/IP65 |
|
|
|
----------------------------------------------------------------------- |
|
|
HIGH SPEED MICROPROCESS LENGTH,FLOW CONTROLLER METER(48x48mm) |
Model:MMC48 |
|
|
|
Readout range form -19999 to 99999 digit |
|
Accepts input rates up to 50KHz |
|
Accept input rates 50 or 50000 CPS
can modified
|
|
Five counting modes Front/after edge-up,up/down,direct-up/down,quadrature-up/
down can be modified
|
|
Quadrature sensing up to 4 times resolution |
|
Input scaling multiplied 0.0001 to 9.9999
can be modified
|
|
Two alarm function (optional) |
|
16 bit DAC analog output function (optional) |
|
Digit RS-485 interface function (optional) |
|
Protection class NEMA4/IP65 |
|
|
|
----------------------------------------------------------------------- |
|
|
MICROPROCESS RPM & LINE-SPEED CONTROLLER METER
(PUSHWHEEL TYPE)(48x96mm)
|
Model:MMRP |
|
|
|
Accuracy 0.03% F.S. |
|
Measuring Pulse(TTL,CMOS),Magnetic pick-up signal |
|
Accepts input rates up to 50KHz |
|
Dual input math function B-A,B/A,(B/A-1),1-(B/A),B/(A+B) |
|
Display type of RPM or line-speed
can be modified
|
|
Input pulse of revolution can be modified(1~99999 pulse/revolution) |
|
Two alarm function)(optional) |
|
16 bit DAC analog outpu function(optional) |
|
Digit RS-485 interface function(optional) |
|
|
|
----------------------------------------------------------------------- |
|
|
6 DIGITAL HIGH SPEED MICROPROCESS PANEL CONTROLLER METER (DISPLAY 0.56")(48x96mm) |
Model:MMX-H |
|
|
|
Accuracy
0.01% F.S.±3digit |
|
Measuring DCA/DCV/Potentiometer/
Transmitter/Load
Cell/Resistor/etc......
|
|
Dual input math function(A,B,A+B,A-B, K-(A+B)) |
|
Programmable
rate -199999~999999 digit
|
|
High speed sampling times 2000Hz |
|
Auto-tracing compensation for Zero-area value(<0.1%F.S.) |
|
Display auto zero/hold/reset function |
|
Max. four
alarm function (optional) |
|
16
bit DAC analog output function (optional) |
|
Digit
RS-485 interface function)(optional) |
|
|
|
----------------------------------------------------------------------- |
|
MULTI-FUNCTION
RS-485 CONTROLLER METER |
(24x48mm) |
Model:MMX-RSMS |
|
|
|
Analog
output accuracy ±0.05%
F.S. |
|
Readout
range from -19999~99999 digit |
|
Calibrator
analog output for DC4~20.000mA/0~20.000mA/0~10.000V |
|
Modbus
RTU mode for RS-485 protocal |
|
Two
relay output function (optional) |
|
16
bit DAC analog output function (optional) |
|
Dimension
small and High stability |
|
|
|
----------------------------------------------------------------------- |
|
|
MULTI-FUNCTION
RS-485 CONTROLLER METER (DISPLAY 0.8")
(48x96x85mm)
|
Model:MMX-RSM |
|
|
|
Analog
output accuracy ±0.05%
F.S. |
|
Readout
range from -19999~99999 digit |
|
Calibrator
analog output for DC4~20.000mA/0~20.000mA/0~10.000V |
|
Modbus
RTU mode for RS-485 protocal |
|
Four
relay output function (optional) |
|
16
bit DAC analog output function (optional) |
|
Dimension
small and High stability |
|
|
|
----------------------------------------------------------------------- |
|
|
MICROPROCESS
PANEL CONTROLLER METER (DISPLAY
0.8")(48x96x85mm) |
Model:MM3 |
|
|
|
Accuracy
0.05% F.S.±1digit |
|
MeasuringDCA/DCV/ACA/ACV/Potentiometer/ Transmitter/Pt-100/Thermocouple/Load
Cell/ Resistor/etc... |
|
Programmable
rate -19999~99999 digit |
|
Auto
zero and hold and maximum hold function |
|
Max.
four alarm function(optional) |
|
16
bit DAC analog output function(optional) |
|
Digit
RS-485 interface function(optional) |
|
|
|
----------------------------------------------------------------------- |
|
|
MICROPROCESS
DUAL ANALOG INPUT
(MATH FUNCTION)PANEL CONTROLLER
METER
(48x96mm)
|
Model:MM2D-D |
|
|
|
Accuracy
0.03% F.S.±1digit |
|
Dual
input measuring and display DCA/DCV/Potentiometer/Transmitter /Pt-100/Thermocouple/Load
Cell/etc...... |
|
Dual
input math function A+B/A-B/AxB/A/B |
|
Programmable
rate -19999~ 99999 digit |
|
Four
alarm function (optional) |
|
16
bit DAC analog output function (optional) |
|
Digit
RS-485 interface function (optional) |
|
|
|
----------------------------------------------------------------------- |
|
|
MULTI-FUNCTION
DC METER(48x96mm) |
Model:MM2D-DT |
|
|
|
Accuracy
0.03% F.S.±1digit |
|
Measuring
and display DCV/DCA/W/KW/WH/KWHÉ) |
|
Programmable
rate 0 to 99999 digit(rate),0 to 9999999999
digit(totalizer) |
|
Four
alarm function (optional) |
|
16
bit DAC analog output function (optional) |
|
Digit
RS-485 interface function)(optional) |
|
|
|
|
|
----------------------------------------------------------------------- |
|
|
PULSE/ANALOG INPUT FLOW RATE/TOTALIZER CONTROLLER METER |
Model:MAFRT |
|
|
|
Accuracy
0.05% F.S.±1digit |
|
Measuring
and display rate(5 digits)/ batch(6 digits)/totalizer(10
digits) |
|
Display
flow unit TON/M3/Liter/GAL/CC
can be modified
|
|
Programable
time base(1 or 60 or 3600 or
86400) second |
|
Math-rootextractor function,
rootextractor contain 0.5/1.5/2.5
|
|
Synchronize totalizer of pulse output function |
|
Correction(16 segments) for non-linearity function(optional) |
|
Four
alarm function (optional) |
|
16
bit DAC isolating analog output function(optional) |
|
Digit
RS-485 interface function(optional) |
|
16Lr |
|
----------------------------------------------------------------------- |
|
|
PULSE/ANALOG
INPUT FLOW RATE/TOTALIZER/BATCH COTROLLER
(two-stage)METER(48x96mm) |
Model:MRT-B |
|
16Lr
|
|
Accuracy
0.05% F.S.±1digit |
|
Measuring
and display rate(5 digits)/ batch(6 digits)/totalizer(10
digits) |
|
Display
flow unit TON/M3/Liter/GAL/CC
can be modified
|
|
Programable
time base(1 or 60 or 3600 or
86400) second |
|
Prestop
counting function |
|
Two-counting
mode Up/Down for
batch controller
|
|
Front
panel push buttons allow the operator to start/stop/batch
reset function |
|
Synchronize totalizer of pulse output function |
|
Protection
class NEMA4/IP64 |
|
|
|
|
|
----------------------------------------------------------------------- |
|
5 DIGIT MICROPROCESS COUNTER,(Low
Power)
(24x48mm)
|
Model:MC24
|
|
|
|
|
Accepts
input rates up to 10KHz |
|
Four counting modes Up,Down,Up/Down, quadrature
can be modified |
|
Quadrature sensing up to 4 times resolution |
|
Input scaling multiplied 0.0001 to 9.9999
can be modified
|
|
Dimension small (24x48x48.5mm) and High stability |
|
Discrete
terminal,connector easy |
|
CE
EMC certification |
|
|
|
----------------------------------------------------------------------- |
|
|
ULTRA HIGH SPEED MICROPROCESS LENGTH,
ANGLE CONTROLLER COUNTER
(48x96x85mm)
|
Model:MCHH |
|
|
|
Accepts input rates up to 500KHz |
|
Readout range form -999999 to 999999 digit |
|
Normal counting and rotate for 360 degree counting can be modified |
|
Quadrature sensing up to 4 times resolution |
|
Input scaling multiplied 0.00001 to 9.99999 can be modified |
|
Two
alarm function(optional) |
|
16
bit DAC analog output function (optional) |
|
Digit
RS-485 interface function (optional) |
|
|
|
----------------------------------------------------------------------- |
|
|
6
DIGIT HIGH SPEED MICROPROCESS COUNTER
(48x96x85mm)
|
Model:MCH |
|
|
|
Accepts
input rates up to 50KHz |
|
Accept
input rates 50 or 500 or 50000 CPS can be
modified |
|
Seven
counting modes Front/after edge-up,Front/after
edge-down,up/down,direct-up/down,quadrature-up/down
can be modified |
|
Quadrature
sensing up to 4 times resolution |
|
Input
scaling multiplied 0.00001 to 9.99999
can
be modified
|
|
Seven
output mode N/F/R/Q/C/P/K can be modified |
|
Two
alarm function(optional) |
|
16
bit DAC analog output function (optional) |
|
Digit
RS-485 interface function (optional) |
|
|
|
----------------------------------------------------------------------- |
|
MICROPROCESS
RPM & LINE-SPEED METER
(Low Power)(24x48mm)
|
Model:MR24 |
|
|
|
Accuracy
0.01% F.S. |
|
Accept
input rates up to 50 KHz |
|
Display
type of RPM or line-speed
can be modified
|
|
Display
unit M/min,Y/min,ft/min
can be modified
|
|
Input
pulse of revolution can be modified (1~99999) |
|
Dimension
small (24x48x48.5mm) and High stability |
|
Discrete
terminal,connector easy |
|
CE
EMC certification |
|
|
----------------------------------------------------------------------- |
|
|
MULTI-FUNCTION
MICROPROCESS RPM & LINE-SPEED CONTROLLER
METER(PULSE INPUT") (48x96x85mm) |
Model:MMRH |
|
|
|
Accuracy
0.03% F.S. |
|
Measuring
Pulse(TTL,CMOS), Magnetic pick-up signal |
|
Accepts
input rates up to 200KHz |
|
Accept
input rates 50/500/200000 CPS
can be modfied
|
|
Dual
input math function B-A,B/A,(B/A-1),1-(B/A),B/(A+B) |
|
Display
type of RPM or line-speed
can be modified
|
|
nput
pulse of revolution can be modified (1~99999pulse/revolution) |
|
Four
alarm function(optional) |
|
16
bit DAC analog output function (optional) |
|
Digit
RS-485 interface function (optional) |
|
|
|
----------------------------------------------------------------------- |
|
MICROPROCESS
LENGTH,FLOW CONTROLLER METER
(24x48mm)
|
Model:MMCS
|
|
|
|
|
Readout
range from -19999 to 99999 |
|
Accepts input rates up to 10KHz |
|
Four counting modes Up,Down,Up/Down, quadrature
can be modified |
|
Quadrature sensing up to 4 times resolution |
|
Input scaling multiplied 0.0001 to 9.9999
can be modified
|
|
Two
alarm function(optional) |
|
15
bit DAC analog output function(optional) |
|
Digit
RS-485 interface function(optional) |
|
|
|
----------------------------------------------------------------------- |
|
|
HIGH
SPEED MICROPROCESS LENGTH,FLOW
CONTROLLER
METER )
( PULSE INPUT )
(48x96x85mm)
|
Model:MMCH
|
|
|
|
Readout
range from _19999 to 99999 |
|
Accepts
input rates up to 50KHz |
|
Accept
input rates 50 or 500 or 50000 CPS
can be
modified |
|
Five
counting modes front/after edge-Up,Up/Down,Direct-Up/Down
Quadrature-Up/Down can be modified |
|
Quadrature
sensing up to 4 times resolution |
|
Input
scaling multiplied 0.0001 to 9.9999
can be
modified
|
|
Four
alarm function (optional) |
|
16
bit DAC analog output function (optional) |
|
Digit
RS-485 interface function (optional) |
|
|
|
----------------------------------------------------------------------- |
|
|
SIX-FUNCTION
AC POWER METER,1P2W,
(24x48mm)
|
Model:MMS-P |
|
|
|
Accuracy
0.1% F.S. |
|
Measuring
and display ACV/ACA/KW/Power factor/Frequency/KWH |
|
ACA/ACV/WATT
for True RMS |
|
Surage
test 4KV(1.2x50us) |
|
Dimension
small (24x48x48.5mm) and High stability |
|
Discrete
terminal,connector easy |
|
|
|
----------------------------------------------------------------------- |
|
|
MULTI-FUNCTION
POWER METER )(1P2W)
(48x96mm)
|
Model:MMP-1 |
|
|
Accuracy
0.1% F.S. |
|
Measuring
and display ACV/ACA/W(KW)/
Power Factor/Frequency/WH(KWH)
|
|
ACA/ACV/Watt
for True RMS |
|
Surage
test 4KV(1.2x50us) |
|
Four
alarm control function (optional) |
|
Digit
RS-485 interface function (optional) |
|
16
bit DAC analog output function (optional) |
|
|
|
|
----------------------------------------------------------------------- |
|
|
3
PHASE AC VOLTAGE/CURRENT METER
(96x96mm)
|
Model:MMP-VI
|
|
|
|
Accuracy
0.15% F.S. |
|
Measuring
ACV-line/ACV-phase/A |
|
Measuring
ACV/ACA total harmonic distortion (THD),up
to 31th harmonic |
|
CT
rate/PT rate can be modified(1 to 9999) |
|
Surage
test 4KV(1.2x50us) |
|
Four
alarm control function (optional) |
|
Digit
RS-485 interface function(Optional) |
|
|
|
----------------------------------------------------------------------- |
|
SLIMMED DOWN MODE
MULTI-FUNCTION POWER METER (48x96mm) |
Model:MMP-3S |
|
|
Analog
output accuracy ±0.15%
F.S. |
|
Measuring and
display ACV/ACA/W(KW)/
Power Factor/Frequency/WH(KWH)
|
|
ACA/ACV/WATT for
TRMS) |
|
Input measurement network can be
selectives(1P2W/1P3W/3P3W/3P4W) |
|
CT rate (1 to 9999)/
PT rate (1.0 to 999.9)
can be modified |
|
Three alarm control
function (optional) |
|
Digit RS-485
interface function (Optional) |
|
|
|
|
|
----------------------------------------------------------------------- |
|
HIGH DIELECTRIC STRENGTH DC SIGNAL ISOLATED TRANSMITTER |
Model:TDH |
|
|
Accuracy 0.1% F.S. |
|
Wide selsction of input/output range |
|
Dielectric strength 5KVac/1min.(input/output/power) |
|
Surge isolation voltage,Vpeak =10KV(1.2x50us,input/output) |
|
Dimension small & High stability |
|
|
|
|
|
----------------------------------------------------------------------- |
|
PROGRAMMABLE PULSE SCALER ISOLATED
TRANSMITTER |
Model:
TFP |
|
|
Maximum input frequency 10KHz |
|
A
variety of input and output selection |
|
Wide range of pulse input premultiplied (0.1 to
1.0) and the pre-addition (1-165000) Function |
|
Dielectric strength 2KVac/1 min.(input/output/power |
|
Wide input
range for auxiliary power |
|
Dimension
small & High stability |
|
|
|
----------------------------------------------------------------------- |
|
PROGRAMMABLE DC TO FREQUENCY ISOLATED TRANSMITTER |
Model:
TDF |
|
|
Accuracy 0.1%F.S. |
|
Maximum output frequency 100KHz |
|
Wide range of pulse output functions
0.006Hz to
100KHz
|
|
Wide range of pulse input premultiplied
(0.1 to
1.0) and the pre-addition
(1-165000) Function
|
|
Dielectric strength 2KVac/1 min.(input/output/power |
|
Wide input
range for auxiliary power |
|
Dimension
small & High stability |
|
|
|
|
----------------------------------------------------------------------- |
|
ULTRA
SLIM TYPE TEMPERATURE ISOLATED TRANSMITTER(102x7.5x102mm) |
Model:SSTMT |
|
|
Accuracy
0.1%F.S.(Pt-100),0.2%F.S.±0.5¢J(CJC)(TC) |
|
Input
sensor type (Pt-100/J/K/T/E/R/S/B)
and output
range(-1999.9~9999.9¢J/¢K)
can be
modify for handly meter)
|
|
Wide
switchable select DC output ranges
over 20
standard process signal
|
|
Thermocouple
input burnout protection function |
|
Dielectric
strength 1.5KVac/1 min.
(input/output)
|
|
Wide
input range for auxiliary power |
|
CE
EMC certification |
|
|
|
----------------------------------------------------------------------- |
|
SLIM
TYPE FREQUENCY ISOLATED TRANSMITTER &
CONTROLLER METER RELAY |
Model:SMFTR |
|
|
Accuracy
0.03% F.S. |
|
Accepts
input frequency rate 50Hz or 50KHz
can be
modified
|
|
Measuring
Pulse(TTL,CMOS),Switch contact Magnetic pick-up
signal |
|
Input
range from 0.01Hz to 50KHz |
|
Max.
two alarm function (optional) |
|
16
bit DAC analog output function (optional) |
|
Digit RS-485 interface function (optional) |
|
Wide
input range for auxiliary power |
|
Dimension
small & Higt stability |
|
|
|
----------------------------------------------------------------------- |